100 °C to 1000 °C Thermocouple Temperature Meter Circuit

In this post I have explained a simple op amp based thermocouple temperature meter circuit which can be used for measuring high temperatures in the range of 100 °C to 1000 °C, in heaters, furnaces, kilns tec.

What is a Thermocouple

A thermocouple is a simplest and the cheapest form of temperature sensor device, built using a couple of dissimilar metals. The two dissimilar metal wires are tightly joined or fused at one of their ends, while the opposite open ends are attached to a sensitive milivoltmeter or an op amp circuit.

When the fused end of the wire is heated, current starts flowing through the wire and a potential difference begins building up across the heated end and the opposite side cold ends. As a result, the meter starts indicating a potential difference, which is directly proportional to the temperature difference between the opposite ends of the wire, or between the hot end and the cold end.

Basic Working of the Project

In this 100 °C to 1000 °C thermocouple temperature meter circuit project, a couple of special alloy metals (Chromel/Alumel) are needed with their ends joined or fused together. For example, one of ends of a CHROME wire and an Aluminum wire could be twisted tightly and the other ends connected to a millivolmeter.

Now If you heat the twisted ends of the wires, you will find a tiny amount of electricity being generated across the free ends of the wires and a deflection appearing on the meter needle.

However, unlike a thermistor, a thermocouple response is not dependent on the amount of heat applied to the fused ends, rather the meter reading will be proportionate to the heat difference between the twisted fused ends of the wires and the ends that are joined to the meter.

The twisted or the fused ends of the thermocouple wire is called the "hot end" and the opposite sides ends are called the "cold ends". Therefore the electrical potential developing across the cold ends is actually proportionate to the difference between the temperature at the hot end and the cold end of the thermocouple wire assembly.

For example, suppose if we find the meter reading increasing at a rate of 4 mV per 100 °C applied at the fused ends of the wires, and the temperature at the cold end connected to the meter is 22 °C, then with the meter reading at 4 mV would indicate that the actual temperature across the fused end is 100 + 22 = 122 °C.

Circuit Description

The figure of a thermocouple meter circuit shown below is probably the simplest of its kind. It employs a single IC 741 op amp as the active device, a few resistors and a mA meter for displaying the temperature reading.

The power is applied from a couple of 9 V PP3 batteries. THe gain of the meter is adjusted and set for all the temperature ranges universally through the preset P1. This setting is done depending on the range and value of the mA meter. The preset P2 is used for adjusting the offset output voltage from the IC 741 op amp. It is adjusted until the needle is pushed to exact zero mark, while the system is not detecting any temperature.

The resistive divider created using R3 and the preset P3 enables the ambient temperature correction adjustment for the meter.

This simple thermocouple temperature meter circuit features two handy temperature ranges to select from, one is 0 to 100, and the other is 0 to 1000. This range cn be selected with an quick toggling of the selector switch K1.

The Chromel/Alumel thermocouple sensor input is plugged into the circuit through an ordinary 3.5 mm jack, connected to the selector switch K1.

When the thermocouple (TC) is plugged into K1, it shorts circuits the non-inverting input of the op amp to ground. Next, if we remove the TC from K1, the (+) input of the op amp is removed from the ground, an at this meter the meter must show zero. If it doesn't then adjust the offset null preset P2 until the needle reaches the zero point on the meter.

After this connecting the TC to the K1 socket, must keep the meter needle at zero until a temperature difference is created across the two ends of the TC. In case you find a slight deviation on the meter needle side due to ambient temperature difference across the "hot end" and "cold end" of the TC, this may be corrected by carefully adjusting the P3 preset, until the needle indicates the ambient temperature on the meter. Now, your thermocouple meter is all set for use.

How to Set Up

In the above paragraph I have explained the basic procedure for setting up the 3 presets of the unit. The following explains the precise method of setting up the thermocouple temperature meter circuit.

Parts List

PCB Design

Wiring Layout

Another Simple Thermocouple Amplifier Circuit

A thermocouple usually comprises of two different metals soldered or welded together at one end, in this case iron and constanan.

When the temperature at the weld fluctuates, the e.m.f. generated across terminals A and B is applied to the non-inverting input of comparator ICI.

The e.m.f. is compared to a 0.7 V reference voltage provided to the opamp's inverting input. The potential across terminals A and B is similarly 0.7 V when the temperature at the thermocouple's weld is around 150 °C.

The comparator subsequently switches, causing the LED to illuminate, signalling that the intended temperature threshold is reached. The constantan terminal must be attached to A, while the iron terminal must be soldered to B.