Site icon Homemade Circuit Projects

3 Simple Frequency Counter Circuits Discussed

frequency 1

frequency 1

In this post we are going learn how to construct 3 different frequency counter circuits using ordinary components and ICs which will showcase the measured frequency on 7 segment displays. The first circuit which uses 4026 ICs can measure frequencies up to 1 MHz and the circuit is user calibrated. 

We will Learn About:

Block diagram:

counter using 4026 IC block diagram

The proposed frequency counter circuit is based on the above architecture which is very simple and the circuit can measure up to 1 MHz frequency. The input frequency signal can be alternating current or DC pulses up to 12V peak. 

A continuous input signal with an unknown frequency is fed to a block of circuit consisting of logic gates and a monostable multivibrator. This block will make sure that right amount of train of pulses are passed to the next stage of the circuit.

The next stage is display driver and counter, both the functionalities are embedded in to one and this stage is responsible for driving the 7 segment displays and also increments the count on the display as per the input signal from previous stage.  

Working principle of the proposed frequency counter circuit:

Frequency is defined as number of oscillations per second (measured in hearts); to measure the frequency of a signal we just need to count the number of oscillations that occurred in one second time frame. 

In the block diagram, we have a block dedicated for counting which counts the number of pulses that you input for measuring; now we need to stop the input signal at the counter section as we reach precisely one second.

To do this we are utilizing a timer which is tuned to output HIGH signal for 1 second and after the one second the input measuring signal gets cut-off to the counter section and the display will freeze. Now we will read the number of oscillations occurred in one second on the display and that’s your measured reading.  

Now let’s try to implement the above working principle.

Circuit diagram:

The circuit diagram for the proposed frequency counter is segregated in to three parts for the purpose understanding them better. 

Display and counter section:

The display and counter section is responsible for driving the common cathode 7 segment display correctly and to count the signal and increment the number on the display.

counter using 4026 IC

The above diagram shows how the 4026 ICs can be cascaded for measuring or counting frequency over a 6 digit display, each display being connected with each IC 4026. Each IC 4026 supports a single common cathode 7 segment display, and thus a total of six 7-segments displays can be connected with the above shown circuit.

The following image gives a magnified and elaborate details regarding how each 7-segment display module can be configured with each of the 4026 ICs in the above figure.

E:\Working\Homemade-circuits\7 Segment frequency counter using IC 4026\Images\IC4026 to CCD.jpg

The above circuit consists of six IC 4026s which takes care of counting and displaying, one push button is provided to reset the count on the display to zero and one 10K pull down resistor is used. To understand how exactly the above circuit works we need to understand the pin description of the IC 4026. 

Pin diagram of IC 4026:

4026 chip compressed

Now let’s come back to the circuit. The IC 4026s are cascaded to 5 stages so that we can get a maximum reading up to 999999 or 1 million (minus 1), hence we can measure frequencies up to 1 MHz.

The right most IC receives the frequency signal to be measured, the right most IC will count up to 9 and when 10th pulse arrives, the count on its respective 7 segment display turns “0” and the very next IC 4026 at left hand side turns 1, this is because the IC’s carryout pin 5 is connected to clock pin 1 of the IC present at the left hand side. By connecting all other ICs in this fashion we will get a counter circuit that can count up to 999999.

A reset button is provided to reset the count of all 7 segment displays to “000000” when needed. A 10K pull-down resistor pulls the reset pin 15 to ground during normal use and when the reset button is pressed Vcc gets applied on pin 15. 

Frequency sampling circuit:

7408 circuit
555 monostable with push button

The sampling circuit is responsible for sending the correct number of pulses to the counter stage. This circuit will chop the continuous signal that you are applying at the input to one second worth of signal samples.  

The output of AND gate IC 7408 (pin 3) is connected to display counter stage and the above illustrated (first circuit) has two inputs, one from the measuring input and one from monostable multivibrator (2nd circuit).

The signal is applied to the base terminal of the transistor and the output of the transistor (collector) is connected to the one of the input of logic AND gate. The purpose of the transistor is to provide high input impedance (resistance) to reduce loading effect on the input signal and also we can apply a much higher voltage at input (recommended maximum is 12V).

Since the transistor can only make its output go LOW, we need to connect a pull-up resistor to the collector pin, so that the input to AND gate can be both HIGH and LOW.

In case if you are applying alternating current signal, polarity can be ignored, in case of DC pulsating signal make sure that ground of input circuit is connected to ground of measuring circuit.

The monostable multivibrator is responsible for delivering 1 second HIGH signal to the other input terminal of AND gate. By doing so the measuring input frequency signal pass to the counter circuit only for 1 second (as per the definition of frequency) thus the unknown frequency gets displayed.  

The monostable multivibrator is built using IC 555 and few passive components to set its output duration. A 47K preset or potentiometer is provided so that the user can calibrate the output duration to exactly 1 second.

When you press the measure button the IC 555’s pin 3 outputs a high signal for 1 second (assuming you set for one second) after that the output at pin 3 will stay low until you push it next time. When you press the “measure button” a LED lights up to indicate that the frequency is getting sampled. 

Calibration of frequency counter:    

The user needs to calibrate the circuit properly only then you can get a correct reading for an unknown frequency.

  1. With fully completed setup turn it ON; apply an input reference frequency of 1 KHz from a function generator. In case you don’t have a function generator use a 0-6V step down transformer and apply the AC 6V at the input, now you need to assume 50 Hz as its reference frequency.
  2. Press measure button, now you will get some random frequency measurement on the display. Now press reset button to bring the count to “000000”.
  3. Adjust the provided pre-set resistor / POT and retake the measurement until the display shows the reference frequency value that is 50 Hz or 1000 Hz. 
  4. The accuracy of measuring unknown frequency will be only as good as the calibration.
  5. When you bring the readings on the display close to the reference value, your machine is ready to measure unknown frequencies.

The first frequency counter circuit concept discussed above involved the IC 4026 for the intended frequency measurements over 7 segment common cathode displays.

Now I have explained a couple of more circuits using IC 74LS47 and IC 4033 and see how these ICs can be configured into specific frequency counter designs, as I have explained below.

2) Frequency Counter Using IC 74LS47

The second frequency counter diagram shown below can be understood with the following points:

Simple Frequency Counter circuit

You may also want to Read: 5 Digit Frequency Meter Circuit


1. The IC 555 is configured in an astable mutivibrator mode (AMV).

2. AMV is a configuration in which the IC555 generates alternate high and low pulses at its pin number 3.

3. These pulses are simply the generation of positive voltages in succession at a certain rate; say for example 20 positive and negative alternate voltage peaks in one minute. The capacitor and resistor values can be adjusted for adjusting the generated pulse rate.

4. In the circuit the 74LS90and 74LS47 are used for counting the above pulses from the IC555.

5. The IC74LS90 accepts the pulses from the IC555 at its input pin no.14.

6. Its internal circuit converts these pulses in the form of special codes (binary) and fed in a certain sequence to the decoder IC 74LS47 through its output pin no.12,9,8,11.

7. The above codes are accepted by the decoder IC 74LS47 at its input pin nos.7,1,2,6 in the same above sequence.

8. The IC74LS47 now decodes this binary information and illuminates the LED display bars in such a way that it starts displaying the numbers 1 to 9 in response to the pulses generated by the IC555, meaning, the first pulse from the IC555 displays a no.1 over the right hand side display, the next pulse makes it display the number 2, then 3 and so on until the display reaches the number 9.

9. During the above procedure the left hand side display continues to show the number zero.

10. However the moment the right hand side display reaches the number 9, the next pulse overflows from pin 11 of the right IC74LS90 and becomes available to pin 14 of the left IC 74LS90 which now repeats the above procedure.

11. So now the left hand side begins continuing the counting by displaying the numbers 1 to 9 and we witness the ongoing counting with the displays modules together showing the number 11 until the number 99.

12. That's the maximum number of digits the shown counter design can display at the maximum.

13. For making the counter a three digit counter or a four digit counter, simply the above stages may be added in the same pin out sequence as the two modules are connected in the given diagram.

14. The input at the pin 14 of the first module can be replaced with any type of pulse that needs to be monitored or which needs to be counted.

The pins of the ICs which are connected to the positive and the negative points of the power supply are the supply input pins of the respective ICs which require precisely 5 volts for operating.

The resistors R1 to R7 on each display are connected for limiting current to the display LEDs so that a constant illumination is maintained and also for safeguarding the display LEDs from getting damaged.

3) Frequency Counter Circuit Using a Single IC 4033

The third circuit concept shown below can be also used for measuring or counting frequency or Hz. The IC is very simple to make and utilizes just a single IC 4033 and a common cathode display as the main ingredients.

Introduction

If higher frequencies in the the order of two or three digits are required to be measured, then simple the number of modules can be connected in series as described.The simple frequency counter circuit shown below will effectively convert any pulse at its input into a display over the 7- segment cathode block.The IC has an internal BCd to 7 segment translator which directly converts the pulses at its input to readable numerical bars at the connected display block.

Circuit Operation

A single IC 4033 is able to handle only one common cathode display block and therefore the shown circuit is able to show numbers from 0 to 9 in response to the relevant clocks applied at its input.

The IC may be easily reset at any point. For example suppose 6 clocks were applied at the input and the the display now reads 6, it can be reverted to zero simply by pressing the shown push button, if needed.

Pin #1 is the input where the clock or the pulses are applied for counting.

In order to make the counter able to count to two digit or 3 digit or 4 digit etc. just include integrate the relevant number of modules as shown in the diagram and connect their outputs in the following manner:

Connect pin #5 of the first module to the clock input of the next module and connect pin #5 of the second module to clock input of the third module and so on.

Make the reset pins common, so that a single push button can be used for resetting all the modules at once.
Supply terminals will also need to be made into common rails.

A capacitor of 0.1uF should be connected close to the supply rail for decoupling purpose.

Circuit Diagram

simple 4033 IC frequency counter circuit
Exit mobile version